Combustion by-products, corrosion: Corrosivity of combustion by-products used as fill around carbon steel structures (NT MAT 001)

  • Report #: NT MAT 001
  • Approved: June 1999
Download pdf Size: 796.69 KB

Abstract

  The aim of the test method is to provide an assessment of the corrosivity on carbon steel of combustion by-products from power and district heating plants before and after accelerated ageing at 40 °C in a measuring cell made for the purpose. The by-products are wetted by capillary action without forced wetting or sprinkling simulating rain. The corrosion conditions are characterised by:
  • Resistivity development due to capillary action.
  • Corrosion potentials.
  • The corrosion rate.
  • Macro corrosion elements.
  • Need for cathodic protection.
This method represents a realistic tool to estimate corrosion of carbon steel in fill consisting of modern by-products, where precipitation is drained off and other wash outs are avoided in order to reduce pollution of ground waters etc.  